NGHIÊN CỨU SỬ DỤNG THIẾT BỊ LẤY MẪU KHÔNG KHÍ THỤ ĐỘNG VỚI PHIN LỌC XỐP POLYURETHANE ĐỂ QUAN TRẮC PCDD/PCDF THEO MÙA

Trịnh Khắc Sáu1, Nguyễn Thị Thu Lý1
1 Phân viện Hoá - Môi trường, Trung tâm Nhiệt đới Việt - Nga

Nội dung chính của bài viết

Tóm tắt

A STUDY ON USING PASSIVE AIR SAMPLER WITH POLYURETHANE FOAM FILTER FOR SEASONAL MONITORING PCDDs/PCDFs

In the article the application of passive air sampler with PUF filter for seasonal monitoring PCDDs/PCDFs in Hanoi is studied. The efficiency of native PCDDs/PCDFs retention on PUF filters in summer, autumn, winter and spring is very high ranging from 87.2% to 89.6%. The 13C-labeled PCDDs/PCDFs standards added  to  the  PUF  filters  from  the  beginning of  the  sampling are  stable.  Their recovery is found from 56,5% to 146,3%, which satisfies the requirements of sampling and analytical methods. The seasonal properties and pollution level of PCDDs/PCDFs congeners in the air at the study spot are quite similar. It is shown that the passive air sampler with PUF filter is feasible and suitable for seasonal monitoring PCDDs/PCDFs in air in tropical climate.

Chi tiết bài viết

Tài liệu tham khảo

1. UNEP, Guidance on the global monitoring plan for persistent organic pollutants, Geneva, Switzerland, May 2007, p.47-62.
2. Gouin T., Harner T., Blanchard P., Mackay D., Passive and active air samplers as complementary methods for investigating persistent organic pollutants in the Great Lakes Basin, Environ. Sci. Technol., 2005, 39:9115-9122.
3. Pozo K., Harner T., Wania F., Muir D.C.G., Barrie L.A., Jones K.C., Global Atmospheric Passive Sampling (GAPS) Study, Organohalogen Compounds, 2005, 67:1323-1326.
4. Pozo K., Harner T., Wania F., Muir D.C.G., Jones K.C., Barrie L.A., Toward a global network for persistent organic pollutants in air: Results from the global atmospheric passive sampling study, Environ. Sci. Technol., 2006, 40:4867- 4873.
5. Lee S.C., Harner T., Pozo K., Shoeib M., Wania F., Muir D.C.G., Barrie L.A., Jones K.C., Polychlorinated naphthalenes in the global atmospheric passive sampling study, Environ. Sci. Technol., 2007, 41:2680-2687.
6. Estellano V.H., Pozo K., Harner T., Franken M., Zaballa M., Altitudinal and seasonal variations of persistent organic pollutants in the Bolivian Andes mountains, Environ. Sci. Technol., 2008, 42:2528-2534.
7. Pozo K., Harner T., Lee S.C., Wania F., Muir D.C.G., Jones K.C., Seasonally Resolved Concentrations of Persistent Organic Pollutants in the Global Atmosphere from the First Year of the GAPS Study, Environ. Sci. Technol., 2009, 43:796-803.
8. Pozo K., Harner T., Shoeib M., Urrutia R., Barra R., Parra O., Focardi S., Passive-sampler derived air concentrations of persistent organic pollutants on a north-south transect in Chile, Environ. Sci. Technol., 2004, 38: 6529-6537.
9. Trịnh Khắc Sáu, Nghiêm Xuân Trường, Lê Bảo Hưng, Nguyễn Thanh Tuấn, Đánh giá khả năng sử dụng phin lọc xốp polyurethane lấy mẫu không khí thụ động phân tích PCDD/PCDF, Tạp chí Hoá học, 2012, 50 (4A):391-394.
10. US. Environmental Protection Agency, Method 1613B Tetra- through octa- chlorinated dioxins and furans by isotope dilution HRGC/HRMS, Washington, DC, 1994, p.1-86.
11. Sau T.K., Truong N.X., Hung L.B., Khue D.N., Net N.X., Son L.K., Tuan N.T., Dung N.T., The characteristics of dioxin pollution in hotspot area and the adsorption isotherms on the activated carbons, Organohalogen Compounds, 2008, 70:554-557.
12. UNEP, Guidance on the global monitoring plan for persistent organic pollutants, Geneva, Switzerland, May 2007, p.132-133.